Information Name: | Hills ups power supply, Emerson, apc, Merlin Gerin, brand batteries |
Published: | 2013-05-27 |
Validity: | 30 |
Specifications: | 3c3 40 |
Quantity: | 40000.00 |
Price Description: | |
Detailed Product Description: | Hills of UPS 3C3-EX40KS Specification Type / Model Hills UPS power 3C3-EX40KS Rated Capacity / In 40000VA/32000W Input voltage / Input voltage range (210VAC ~ 475VAC) Output voltage / Output voltage range 380VAC / 220VAC3Ф4W) Output Frequency / Output frequency Mains synchronization with the input [mode] when the mains frequency exceeds (46 ~ 54) Hz range, the output frequency is 50 (1 ± 0.2%) Hz input bypass voltage range ± 15% Standby Time / Backup time 20 minutes to 8 hours, optional charging time / Charging period ≤ 10 hours Output socket (GB) terminal block conversion time / Transfer time zero conversion software interface / Interface RS-232 + Intelligent Slot alarm system / Alarm System Battery: apparent low battery alarm: overload continuous audible alarm can be connected at the other ports / Other ports can choose to install Winpower CMC monitoring card, SNMP card, RS485, AS400 card, EMD environmental monitors Net Dimensions (width × depth × height) (mm) 470mm × 710mm × 1150mm Transport dimensions ( width × depth × height) (mm) 470mm × 710mm × 1150mm Net weight / Net weight 114kg Shipping Weight / Shipping weight 164kg Host Color / Host Color Black Audible noise / Hearing noise from equipment surfaces 1M at: 38 dBA Operating Environment / Environment of Performance Temperature / 0 ° C-40 ° C, humidity / 20% -90% Storage height / Storage height 0-15000m operating altitude / Operation height 0-3000m external battery Nominal voltage / rated charging voltage 348VDC/360V/384VDC super powers contained 120% 10min, 150% 30s Warranty Service / Warranty Service 3 year onsite repair Hills UPS power 3C3-EX40KS Introduction Hills UPS power performance and advantages of the castle 3C3 EX Series UPS each phase by a separate PFC circuit converts AC into DC and then through the inverter (Inverter) the DC into AC output. While providing a separate controller, the PFC circuit, real-time control and data acquisition, in order to make the whole system more coordinated operation / more timely feedback to the user of the system state. Meanwhile, the battery charging control, effectively extending the battery life. Dual mains input structure to improve overall system reliability. 3C3 EX series also increases the system's protection level, so that products can be dusty industrial environments stable operation. Good industrial environment protection performance can be achieved under standard IP21 degree of protection (to prevent intrusion of solid objects greater than 12mm, a vertical drop of water droplets to prevent intrusion). Requirements for higher dust, optional dust components, improve industrial environments users dustproof, ensuring UPS devices in harsh environments safe operation. N + X parallel redundancy (to support and drive of the battery) machine built and machine function, no additional external accessories, you can achieve up to 8 UPS units in parallel, user-friendly low-cost system expansion. N represents the minimum required by the load number for UPS, X represents the number of redundant UPS, X represents the greater system reliability will be higher. The use of advanced control strategies in parallel redundant operation, the systems can share a set of batteries, saving the user's investment costs. Intelligent management of battery charging and discharging advanced intelligent charging through the control of the CPU, UPS charger according to different environmental conditions, amended charging parameters, providing optimum battery charging. Designed a number of charging, the battery type, the number of cells and the battery charge status to choose the best way. Scientific charging, the battery life has been extended. And can be equipped with a charging unit, so that multiple sets of battery charging time is much shorter back. Front Operation and maintenance functions fully considered positive user space the effective utilization; modular design and maintain a positive, greatly reducing the machine's fault repair time and increase the availability of UPS. High security dual mains input power according to the actual situation with dual mains input or single mains input, allowing users to be more secure electricity supply protection. Rich remote monitoring means providing RS232/RS485, Intelligent Slot (Intelligent Slot) and other monitoring communication interface, can load Hills company CMC card, WebPower card for remote management and monitoring capabilities, but also provides the AS400 card to provide external dry contact interface to facilitate the monitoring requirements of different customers flexible options. High-performance DSP processor fully digital Ti-performance DSP control technology, precise rapid data processing, the output will be more superior performance, reliability and more to improve. Excellent electrical performance overall efficiency up to 93%; provide ECO mode, so that up to 98% efficiency, reducing power loss of UPS. Deal with Chinese grid requirements designed to provide a wide input voltage range of 210VAC ~ 475VAC. The grid can be applied to harsh environments. Excellent input frequency range of the UPS can adapt different power generators and other equipment. IGBT FM intelligent rectifier inverter technology, input power factor of 0.99, low input current harmonics to 3%; output voltage and current performance is more excellent. Powerful overload :110-125% load can run 10 minutes; 125-150% load can run for 1 minute. And has output short circuit protection. More flexible battery configuration 3C3 EX Series UPS can modify the parameter settings, each group must be configured flexibly adjust the number of battery section (32, 30, or 28). With this feature, you can use the UPS process, a small amount of damage to the battery pack in the battery removed, so as to effectively solve the difficulties which may result in damage to individual cells on the battery life of the entire group of questions. Long-Rack UPS power supply design offers a comprehensive long-term machine for users to choose. Configure the appropriate battery pack allows the user to use the discharge time up to 8 hours or so, in order to meet different network environments. Long-term capacity-powerful charge in addition to long-term machine Rack UPS extend the discharge time, recharge the battery capacity is also very strong, you can provide about 4 ~ 9A initial charging current. Rack UPS self-check function can be simulated the situation of power into the battery power mode, this function either through self-test button on the front panel performed at any time, you can also tie Hills monitoring software, on a regular or irregular manner. Strong immunity against electromagnetic interference and radio frequency interference, Rack UPS in accordance with international standards EN50091-2 and IEC61000-4 series of standards designed to effectively improve the safety of the use of the UPS and reliability. Can be used with generators Wide input voltage and frequency range, so Rack UPS with major brands generator with the use of a more extended use of time, while effectively eliminates the adverse generators of electricity, load to provide clean, safe, stable electrical. Rack UPS can be connected inductive load can be connected inductive load (pf = 0.8). If customers have other special needs, can be directly approached Hills company. Flexible configuration, because of the need extensive expansion capabilities to meet customer demand. Line maintenance functions: continuous power supply in case of load safety online service. Remote power function (EPO): When an emergency occurs, you can quickly turn off UPS. And machine components: parallel expansion and parallel redundancy to provide users with the flexibility and power planning more secure protection. Dust components: enhancing products in the industrial environment, dust levels. Isolation Transformers: to provide users with isolation protection. . Hills of UPS 3C3-EX40KS product images Hills UPS power 3C3-EX40KS installation instructions common standby time and battery configuration table (for reference only) after power supply time the number of host cell battery capacity (AH) Battery Cabinet Cabinet Model Number Battery powered 30 minutes a Taiwan 32 65 1 A32-powered one hour a Taiwan 64 100 1 A32-powered two hours a Taiwan 96 100 2 A32-powered three hours a Taiwan 128 100 3 A32-powered four hours a Taiwan 160 100 4 A32-powered six hours a Taiwan 192 100 6 A32-powered eight hours a Taiwan 256 100 8 A32 |
Admin>>>
You are the 7119 visitor
Copyright © GuangDong ICP No. 10089450, Tak Technology Co., Ltd. Beijing Hua Binxin All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 7119 visitor
Copyright © GuangDong ICP No. 10089450, Tak Technology Co., Ltd. Beijing Hua Binxin All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility